Standard Metal Protection Tube Thermocouples
HOW TO CONSTRUCT A PART NUMBER
Table 1 (Style): See Aove style
Table 2 (Connection Head)
HEAD CODES
0 = NO HEAD
1= CAH (CAST ALUMINUM)
2= CIH (CAST IRON)
3= PPH (POLYPROPYLENE)
4= EPH (EXPLOSION PROOF)
5= MAH (MINI ALUMINUM)
6= (SPECIAL)
Table 3 (ANSI Designation)
SINGLE DUAL ALLOY
J SJ Iron/Constantan
K SK Chromel/Alumel
T ST Copper/Constantan
E SE Chromel/Constantan
S SS Platinum vs. Platinum 10% Rhodium
R SR Platinum vs. Platinum 13% Rhodium
B SB Plt 6% Rhd. Vs. Plt 30% Rhd
W SW Tungsten 5 % Rhenium vs Tg. 26% Rh
N SN Nicrosil/Nisil
Table 4 (Junction Type)
CODE# WIRE GAUGE
08 .125”
14 .064”
20 .032”
24 .020”
Table 5 (Protection Tubes)
CODE# MATERIAL MAX TEMP. TUBE O.D. MAX SIZE WIRE GA.
T5 304 S.S. 1650 F 1/8” 20
T6 304 S.S 1650 F 1/4 “ 14
T7 304 S.S. 1650 F 1/2 “ 8
T8 304 S.S. 1650 F 3/4” 20
T9 304 S.S. 1650 F 1” 14
I7 INCONEL 600 2100 F 1/2 “ 8
I8 INCONEL 600 2100 F 3/4 “ 24
F7 446 S.S 2000 F 1-3/4” 8
F8 445 S.S 2000 F 3/4" 8
C5 CARBON STEEL 1200F 1/8" 20
C6 CARBON STEEL 1200F 1/4" 14
C7 CARNON STEEL 1200 F 1/2" 8
C8 CARBON STEEL 1200 F 3/4" 8
C9 CARBON STEEL 1200 F 1" 8
Table 6 (Process length in inches)
SPECIFY LENGTH INCHES
Example: 048 = 48”
Table 7 (Model 630)
COLD LEG LENGTH IN INCHES
IF NOT MODEL 630 USE 00
Table 8 (Options)
CODE
N = None
F = MOUNTING FLANGE